Q&A · installation
How should wire lath be installed for natural stone veneer?
Expanded, galvanized, self-furring diamond-mesh meeting ASTM C847-18 (min 2.5 lb/yd2) should be installed tightly with cups up. Overlap sections by approximately 1 inch and fasten with corrosion-resistant fasteners every 16 inches horizontally on-center and maximum 6 inches vertically.